Basis Info
- Modell Nr.: LPV-150-12
- Ausgabetyp : Single
- Garantie : 2 Jahre
- Ausgangsleistung : 101 - 200W
- Eingangsspannung : Full Range
- Connection Mode : Series Switching Power Supply
- Startmodus : Self-excited Switching Power Supply
- Spannungsregelung : Frequency Modulation Type
- Stromversorgungssystem : Terminal Power Distribution Equipment
- Energieübertragung : Zweiwege-Übertragungs
- Modulation System : PWM
- Bescheinigung : CE , UL , RoHS , CB
- Marke : MEAN WELL
Zusätzliche Informationen..
- Packing: 0.74kg; 20PCS/15.8kg/0.95cuft
- Origin: China
- Production Capacity: 1000PCS Per Month
Produktbeschreibung
Features:
Constant voltage design
180~305 VAC input only
Fully encapsulated with IP67 level
ClassII power unit , no FG
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Fully isolated plastic case
Suitable for use in Dry, Damp and Wet location
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost, high reliability
2 years warranty
DC VOLTAGE: 12V/15V/24V/36V/48V
MODEL | LPV-150-12 | LPV-150-15 | LPV-150-24 | LPV-150-36 | LPV-150-48 | |
OUTPUT | DC VOLTAGE | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 10A | 8A | 6.3A | 4.2A | 3.2A | |
CURRENT RANGE | 0 ~ 10A | 0 ~ 8A | 0 ~ 6.3A | 0 ~ 4.2A | 0 ~ 3.2A | |
RATED POWER | 120W | 120W | 151.2W | 151.2W | 153.6W | |
RIPPLE & NOISE (max.) Note.2 | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±5.0% | |||||
LINE REGULATION | ±1.0% | |||||
LOAD REGULATION | ±2.0% | |||||
SETUP, RISE TIME Note.6 | 500ms, 50ms / 230VAC 500ms, 50ms / 277VAC | |||||
HOLD UP TIME (Typ.) | 18ms/230VAC 20ms/277VAC at full load | |||||
INPUT | VOLTAGE RANGE Note.4 | 180 ~ 305VAC 254 ~ 431VDC | ||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
EFFICIENCY (Typ.) | 87% | 88% | 89% | 89% | 90% | |
AC CURRENT | 1.7A/230VAC 1.5A/277VAC | |||||
INRUSH CURRENT(Typ.) | COLD START 60A(twidth=900μs measured at 50% Ipeak) at 230VAC | |||||
MAX. No. of PSUs on 16A | 2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC | |||||
LEAKAGE CURRENT | 0.25mA / 240VAC | |||||
PROTECTION | OVERLOAD | 110 ~ 150% rated output power | ||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE | 13.5 ~ 17V | 17 ~ 25V | 27 ~ 35V | 40 ~ 49V | 52 ~ 63V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +65ºC (Refer to "Derating Curve") | ||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||
STORAGE TEMP., HUMIDITY | -40 ~ +80ºC, 10 ~ 95% RH | |||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | |||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||
SAFETY & EMC | SAFETY STANDARDS | UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,IP67 approved. Design refer to EN60950-1 | ||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC / 25ºC/ 70% RH | |||||
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A(≤80% load), EN61000-3-3 | |||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A | |||||
OTHERS | MTBF | 703Khrs min. MIL-HDBK-217F (25ºC) | ||||
DIMENSION | 191*63*37.5mm (L*W*H) | |||||
PACKING | 0.74Kg;20pcs/15.8Kg/0.95CUFT | |||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit. 8. Suitable for indoor use or outdoor use without direct sunlight exposure. |
Produkttyp
»
»
»