- Modell Nr.: CDI-E180G280/P315T4
- Anwendung : High-Performance-Transducer , Drei Phase Transducer , Allgemeine Transducer , Einphasen-Transducer , High Frequency Converter Transducer
- Ausgabetyp : Dreifach
- Prinzip der Arbeit : Vector Control Transducer
- Switch Mode : PWM-Steuerung
- Spannung der Stromversorgung : Mittelspannungs Variable Frequency Drive-
- Link der Transformation : AC-DC-AC-Variable Frequency Drive
- Art der DC-Strom : Aktuelle Variable Frequency Drive-
- Funktion : Konstante Drehmoment Universal Type
- Trademark: DELIXI
- Packing: Standard Exporting Package
- Standard: CE, CCC
- Origin: Zhejiang China(Mainland)
- HS Code: 8504409999
- Production Capacity: 10, 000 Per Month
Product Name: China AC Drive, AC Frequency Drive for Motor
* Dear friends, you can tell me your requirements, I will select models for you if needed.
1. "High precision", "high performance", "high cost-effective".
To satisfy the increasingly higher requirements on the industrial production of frequency inverters, Hangzhou Delixi develops a new E series frequency inverter aiming at the market demands. Compared with the old frequency inverters, its precision and performance are improved substantially besides its optimized structure and appearance. Its powerful built-in function may better fulfill the needs of different industries.
2. High control precision
Speed regulation scope
1: 100 (SVC) 1: 1000(VC)
Speed stabilizing scope
0.5%(SVC) 0.02%(VC)
Torque control precision
5% (VC)
3. Rapid torque response
SVC: Torque response < 20ms
VC: Torque response < 5ms
4. High starting torque
SVC: 0.5 Hz may provide 150% starting torque
VC: 0 HZ may provide 180% torque at zero speed
5. Various vector controls of motors are available
E180 Series may drive asynchronous motor and synchronous motor.
6. Diversified menu display modes
7. Function of built-in timer
It has two built-in timers to collect input timing signals and realize the output of timing signals. Such function may be used separately or in any combination.
8. Built-in virtual time-delay relay
It has 5 built-in virtual time-delay relays to conduct simple logic operation for multi-functional output terminals and digital input terminal signals. The logic result may be considered as equivalent to input terminal function and also may be output from the multi-functional output terminals. Moreover, the logic results may be conducted with time-delay and negation operations.
9. Function of built-in operating module
One quad operating module is built in. Such module may conduct simple addition, subtraction, multiplication, division, judgment of size and integral operations. Each operation has 4 input directing addresses and one output directing address. The input directing address is function code.
10. Function of rapid current limiter
In the case the current exceeds the current protection point, the rapid current limiter may keep the current within the current protection point to prevent frequently sending over-current alarm by the frequency inverter and protect the equipment.
11. Excellent capability of power drive control
The maximum drive capability of 24V output power of E-series frequency inverter, equipped with current limiting alarm function, may be 300mA.
The user may use it to supply power to text, touch screen, PLC and relay instead of connecting to an external switch.
Item | Specification | |
Control | Control Mode | V/F control |
Open-loop Vector Control (SVC) | ||
Vector Control (VC) (Not applicable to E100/E102/EM60 series) | ||
Frequency Precision | Digital: 0.02% | |
Analog: 0.1% | ||
V/F Curve | Linear, square root, any V/F | |
Overload Capacity | G-type: 150% rated current for 60s; 180% rated current for 3s | |
P-type: 120% rated current for 60s; 150% rated current for 3s | ||
Start Torque | G-type: 0.5Hz/150% (SVC); 0Hz/180% (VC) | |
Speed Adjustment Range | 1:100 (SVC) 1:1000 (VC) | |
0.5% (SVC) 0.02% (VC) | ||
Torque Precision | 5% (VC) | |
Torque Compensation | Manual torque compensation (0.10%-30.0%); Automatic torque compensation | |
Operating Mode | Key-board, terminal, RS485 communication | |
Basic Type Function | Frequency Source | 14 main sources, 14 auxiliary sources. |
Easy switch between different modes. | ||
Diversified input modes for every source: keyboard potentiometer, external analog, | ||
digital setting, pulse frequency, multi-speed, simple PLC, communication, computing | ||
results, etc. | ||
Torque Source | 14 torque sources, including digital setting, external analog, pulse setting, | |
multi-order, communication, computing results, etc. | ||
Acceleration and Deceleration Time | 4 groups of lines (can be switched through the option terminals); S Curve 1, S Curve 2 | |
Emergency Stop | Interrupt the output instantaneously | |
Multi-speed | 16-shift speeds at most; can be switched by different combination of order terminals | |
Simple PLC | Continuous operation of 16-shift speeds; the acceleration/deceleration time, operating | |
time and frequency source for every shift can be set separately | ||
Inching Control | Inching frequency and inching acceleration/deceleration time can be set separately; | |
Inching can be prioritized in process. | ||
Rotating-speed Track | Track the start speed and operating speed of the inverter's load | |
Length and Distance Control | Length and distance control through pulse inputs | |
Counting | Counting through pulse inputs | |
Swing Frequency | For winding machines in the textile industry | |
Internal PID | Closed-loop process control system is available | |
AV R | Ensure constant output in case of fluctuating grid voltage | |
DC Brake | Quick and stable parking is available | |
Slip Compensation | Compensate the slip deviation due to increased load | |
Hopping Frequency | Prevent resonance with the load | |
Droop Function | Balance the load rate of different motors which drive the same load | |
Timing | Automatic stop at a given time |
Model | Brake Unit | Brake Resistance | Power (W) |
CDI-EM60G0R4S2B | Internal, Max. Current of 8A | 400 | 80 |
CDI-EM60G0R75S2B | Internal, Max. Current of 8A | 200 | 160 |
CDI-EM60G1R1S2B | Internal, Max. Current of 8A | 160 | 200 |
CDI-EM60G1R5S2B | Internal, Max. Current of 15A | 120 | 250 |
CDI-EM60G2R2S2B | Internal, Max. Current of 15A | 80 | 400 |
Model | Brake Unit | Brake Resistance | Brake Resistor Power (W) |
S2 (Single-phase 220V) | |||
CDI-E100G0R4S2B | Internal, Max. Current of 8A | 400 | 80 |
CDI-E100G0R75S2B | Internal, Max. Current of 8A | 200 | 160 |
CDI-E100G1R5S2B | Internal, Max. Current of 15A | 120 | 250 |
CDI-E100G2R2S2B | Internal, Max. Current of 15A | 80 | 400 |
T2 (Three-phase 220V) | |||
CDI-E100G0R4T2B | Internal, Max. Current of 8A | 400 | 80 |
CDI-E100G0R75T2B | Internal, Max. Current of 8A | 200 | 160 |
CDI-E100G1R5T2B | Internal, Max. Current of 15A | 120 | 250 |
CDI-E100G2R2T2B | Internal, Max. Current of 25A | 80 | 400 |
T4 (Three-phase 380V) | |||
CDI-E100G0R75T4B | Internal, Max. Current of 8A | 600 | 160 |
CDI-E100G1R5T2B | Internal, Max. Current of 8A | 400 | 250 |
CDI-E100G2R2T4B | Internal, Max. Current of 15A | 250 | 400 |
CDI-E100G3R7T4B | Internal, Max. Current of 15A | 150 | 600 |
CDI-E100G5R5/P7R5T4B | Internal, Max. Current of 40A | 100 | 1000 |
CDI-E100G7R5/P0R11T4B | Internal, Max. Current of 40A | 75 | 1200 |
CDI-E100G011/P015T4BL | Internal, Max. Current of 50A | 50 | 2000 |
CDI-E100G015/P018.5T4BL | Internal, Max. Current of 75A | 40 | 2500 |
CDI-E100G0185/P022T4 | Internal, Max. Current of 50A Connect to External CDI-BR-50 | 30 | 4000 |
CDI-E100G022T4 | Internal, Max. Current of 50A Connect to External CDI-BR-50 | 30 | 4000 |
Model | Brake Unit | Brake Resistance | Brake Resistor Power (W) |
T2 (Three-phase 220V) | |||
CDI-E180G0R4T2B | Internal, Max. Current of 10A | 350 | 160 |
CDI-E180G0R75T2B | Internal, Max. Current of 10A | 300 | 160 |
CDI-E180G1R5T2B | Internal, Max. Current of 25A | 100 | 250 |
CDI-E180G2R2T2B | Internal, Max. Current of 25A | 75 | 400 |
CDI-E180G3R7T2B | Internal, Max. Current of 40A | 45 | 600 |
CDI-E180G5R5T2B | Internal, Max. Current of 50A | 30 | 1000 |
CDI-E180G7R5T2BL | Internal, Max. Current of 75A | 20 | 1200 |
CDI-E180G011T2 | Internal, Max. Current of 50A (Connect to External CDI-BR-50) | 16 | 2000 |
CDI-E180G015T2 | CDI-BR-100 | 12 | 2500 |
CDI-E180G018.5T2 | CDI-BR-100 | 20/2 | 4000 |
CDI-E180G022T2 | CDI-BR-100 | 16/2 | 4000 |
CDI-E180G030T2 | Internal, Max. Current of 75A (Connect to External CDI-BR-50) | 13.6/2 | 6000 |
T4 (Three-phase 380V) | |||
CDI-E180G0R75T4B | Internal, Max. Current of 10A | 600 | 160 |
CDI-E180G1R5T4B | Internal, Max. Current of 10A | 400 | 250 |
CDI-E180G2R2T4B | Internal, Max. Current of 15A | 250 | 400 |
CDI-E180G3R7/P5R5T4B | Internal, Max. Current of 25A | 150 | 600 |
CDI-E180G5R5MT4B | Internal, Max. Current of 40A | 100 | 1000 |
CDI-E180G5R5/P7R5T4B | Internal, Max. Current of 40A | 100 | 1000 |
CDI-E180G7R5/P011T4B | Internal, Max. Current of 40A | 75 | 1200 |
CDI-E180G011MT4B | Internal, Max. Current of 50A | 50 | 2000 |
CDI-E180G0011/P015T4BL | Internal, Max. Current of 50A | 50 | 2000 |
CDI-E180G015/P018.5T4BL | Internal, Max. Current of 75A | 40 | 2500 |
CDI-E180G018.5/P022T4 | Internal, Max. Current of 50A (Connect to External CDI-BR-50) | 30 | 4000 |
CDI-E180G022/P030T4 | Internal, Max. Current of 75A (Connect to External CDI-BR-50) | 30 | 4000 |
CDI-E180G030/P037T4 | Internal, Max. Current of 50A (Connect to External CDI-BR-50) | 20 | 6000 |
CDI-E180G037/P045T4 | CDI-BR-100 | 16 | 9000 |
CDI-E180G045/P055T4 | CDI-BR-100 | 13.6 | 9000 |
CDI-E180G055/P075T4 | CDI-BR-100 | 20/2 | 12000 |
CDI-E180G075/P093T4 | CDI-BR-200 | 13.6/2 | 18000 |
CDI-E180G093/P110T4 | CDI-BR-200 | 20/3 | 18000 |
CDI-E180G110/P132T4 | CDI-BR-200 | 20/3 | 24000 |
CDI-E180G132/P160T4 | CDI-BR-200 | 20/4 | 36000 |
CDI-E180G160/P185T4 | CDI-BR-400 | 13.6/4 | 45000 |
CDI-E180G185/P200T4 | CDI-BR-400 | 13.6/5 | 45000 |
CDI-E180G200/P220T4L | CDI-BR-400 | 13.6/5 | 54000 |
CDI-E180G250/P280T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G280/P315T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G315/P355T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G355/P375T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G375T4L | CDI-BR-400 | 13.6/6 | 63000 |
CDI-E180G400T4L | CDI-BR-600 | 13.6/7 | 63000 |
CDI-E180G400T4L | CDI-BR-600 | 13.6/7 | 72000 |
CDI-E180G500T4L | CDI-BR-600 | 13.6/8 | 72000 |
CDI-E180G500T4L | CDI-BR-600 | 13.6/8 | 81000 |
CDI-E180G630T4L | CDI-BR-600 | 13.6/9 | 81000 |
CDI-E180G200T4L | CDI-BR-600 | 13.6/9 | 90000 |
CDI-E180P250T4L | 2 CDI-BR-400 | 13.6/10 | 18000 |
WHY CHOOSE US?
Q1.Are you manufacturer or trading company?
A.We are the only manufacturer of electrical products.
Welcome to visit our factory at any time.
Q 2. what's the payment term?
A. We accept T/T, L/C, WESTERN UNION
Q 3. What's the delivery time ?
A. Normal model 1-3days,because we have ability to do the stock.
For big order,it takes about 15-20days.
Q 4. What is the standard of package?
A. Export standard package or special package according to customer requirement
.
Q 5. what kind of product quality your factory offer?
A. We are top 3 from Chinese market.We offer top quality to help client to get more market.
Q 6. Do you accept OEM business?
A. We do OEM .
Q 7.Which market do you already sell?
A.We already ship to Middle East, Asia, Russia ,Afria etc.
Q8. what kind of certificate you have ?
A.We have ISO9001, CE, CCC,etc.