- Modell Nr.: CDI-E180G630T4
- Anwendung : High-Performance-Transducer , Drei Phase Transducer , Allgemeine Transducer , Einphasen-Transducer , High Frequency Converter Transducer
- Ausgabetyp : Dreifach
- Prinzip der Arbeit : Vector Control Transducer
- Switch Mode : PWM-Steuerung
- Spannung der Stromversorgung : Mittelspannungs Variable Frequency Drive-
- Link der Transformation : AC-DC-AC-Variable Frequency Drive
- Art der DC-Strom : Aktuelle Variable Frequency Drive-
- Funktion : Konstante Drehmoment Universal Type
- Trademark: DELIXI
- Packing: Standard Exporting Package
- Standard: CE, CCC
- Origin: Zhejiang China(Mainland)
- HS Code: 8504409999
- Production Capacity: 10, 000 Per Month
Product Name: 630KW AC to AC Frequency AC Drive
* Dear friends, you can tell me your requirements, I will select models for you if needed.
1. "High precision", "high performance", "high cost-effective".
To satisfy the increasingly higher requirements on the industrial production of frequency inverters, Hangzhou Delixi develops a new E series frequency inverter aiming at the market demands. Compared with the old frequency inverters, its precision and performance are improved substantially besides its optimized structure and appearance. Its powerful built-in function may better fulfill the needs of different industries.
2. High control precision
Speed regulation scope
1: 100 (SVC) 1: 1000(VC)
Speed stabilizing scope
0.5%(SVC) 0.02%(VC)
Torque control precision
5% (VC)
3. Rapid torque response
SVC: Torque response < 20ms
VC: Torque response < 5ms
4. High starting torque
SVC: 0.5 Hz may provide 150% starting torque
VC: 0 HZ may provide 180% torque at zero speed
5. Various vector controls of motors are available
E180 Series may drive asynchronous motor and synchronous motor.
6. Diversified menu display modes
7. Function of built-in timer
It has two built-in timers to collect input timing signals and realize the output of timing signals. Such function may be used separately or in any combination.
8. Built-in virtual time-delay relay
It has 5 built-in virtual time-delay relays to conduct simple logic operation for multi-functional output terminals and digital input terminal signals. The logic result may be considered as equivalent to input terminal function and also may be output from the multi-functional output terminals. Moreover, the logic results may be conducted with time-delay and negation operations.
9. Function of built-in operating module
One quad operating module is built in. Such module may conduct simple addition, subtraction, multiplication, division, judgment of size and integral operations. Each operation has 4 input directing addresses and one output directing address. The input directing address is function code.
10. Function of rapid current limiter
In the case the current exceeds the current protection point, the rapid current limiter may keep the current within the current protection point to prevent frequently sending over-current alarm by the frequency inverter and protect the equipment.
11. Excellent capability of power drive control
The maximum drive capability of 24V output power of E-series frequency inverter, equipped with current limiting alarm function, may be 300mA.
The user may use it to supply power to text, touch screen, PLC and relay instead of connecting to an external switch.
Introduction
The CDI-E180-series inverter is a stable and versatile high-performance vector control inverter with optimum control modes such as SVC, V/F control and VC, and is widely used in situations with demanding requirements for speed control precision,
torque respond speed and low-frequency output torque.
Technical Characteristics
Excellent Performance
Due to the new vector control algorithm, the inverter features large start torque, quick torque response
and high control precision to further improve the efficiency of the motor.
Strong Function and Low Cost
The large number of internal function modules such as timer, virtual time-delay relay and math
operation modules are as a whole equivalent to an additional small PLC, so that the cost is significantly reduced.
Easy Operation
A special-purpose function is embedded, and the conversion between the special-purpose function
and the common function is available through one function code, for the convenience of type
selection and flexibility in use.
Flexible Type Selection
The 15kW or below types have standard internal brake units, the 18.5-30kW types can have optional
internal brake units, and the 37kW above types shall be connected with external brake units. The
11kW, 15 kW, 200 kW or above types have standard DC inductors, and 18.5-55kW types can have
optional DC inductors.
Applications
Electric power, textile and chemical fiber, building materials, oil industry, chemical industry, metallurgy, municipal facilities, paper-making, food & beverage and tobacco.
Accessories
E180-I/O expansion card; E180-PG coder expansion card; E180-485 communication expansion card; E180-DP communication expansion card.
E180-ZS injection molding machine expansion card; E180-WSP constant pressure water supply expansion card.
Item | Specification | |
Control | Control Mode | V/F control |
Open-loop Vector Control (SVC) | ||
Vector Control (VC) (Not applicable to E100/E102/EM60 series) | ||
Frequency Precision | Digital: 0.02% | |
Analog: 0.1% | ||
V/F Curve | Linear, square root, any V/F | |
Overload Capacity | G-type: 150% rated current for 60s; 180% rated current for 3s | |
P-type: 120% rated current for 60s; 150% rated current for 3s | ||
Start Torque | G-type: 0.5Hz/150% (SVC); 0Hz/180% (VC) | |
Speed Adjustment Range | 1:100 (SVC) 1:1000 (VC) | |
0.5% (SVC) 0.02% (VC) | ||
Torque Precision | 5% (VC) | |
Torque Compensation | Manual torque compensation (0.10%-30.0%); Automatic torque compensation | |
Operating Mode | Key-board, terminal, RS485 communication | |
Basic Type Function | Frequency Source | 14 main sources, 14 auxiliary sources. |
Easy switch between different modes. | ||
Diversified input modes for every source: keyboard potentiometer, external analog, | ||
digital setting, pulse frequency, multi-speed, simple PLC, communication, computing | ||
results, etc. | ||
Torque Source | 14 torque sources, including digital setting, external analog, pulse setting, | |
multi-order, communication, computing results, etc. | ||
Acceleration and Deceleration Time | 4 groups of lines (can be switched through the option terminals); S Curve 1, S Curve 2 | |
Emergency Stop | Interrupt the output instantaneously | |
Multi-speed | 16-shift speeds at most; can be switched by different combination of order terminals | |
Simple PLC | Continuous operation of 16-shift speeds; the acceleration/deceleration time, operating | |
time and frequency source for every shift can be set separately | ||
Inching Control | Inching frequency and inching acceleration/deceleration time can be set separately; | |
Inching can be prioritized in process. | ||
Rotating-speed Track | Track the start speed and operating speed of the inverter's load | |
Length and Distance Control | Length and distance control through pulse inputs | |
Counting | Counting through pulse inputs | |
Swing Frequency | For winding machines in the textile industry | |
Internal PID | Closed-loop process control system is available | |
AV R | Ensure constant output in case of fluctuating grid voltage | |
DC Brake | Quick and stable parking is available | |
Slip Compensation | Compensate the slip deviation due to increased load | |
Hopping Frequency | Prevent resonance with the load | |
Droop Function | Balance the load rate of different motors which drive the same load | |
Timing | Automatic stop at a given time |
Item | Specification | |
Enhanced Function | Internal Virtual Time Delay Relay | Simple logic programming for the multi-functional output terminals and the digital input terminals. |
The logic results can be equivalent to the digital input terminal function, and can be output through | ||
the multi-functional output terminals | ||
Internal Timer | Two internal timers to collect timing input signals and to output timing signals. | |
The two timers can be used separately or together | ||
Internal Math | One internal 4-way math operation module for elementary arithmetic operations, numerical | |
Operation Module | magnitude judgment and integral operation | |
Communication | E100 | The control panel has a RS485 communication interface which supports standard MODBUS-RTU |
protocol | ||
E102/E180/EM60 | The control panel does not have a RS485 communication interface, and an external 485 | |
communication expansion card shall be connected. Support standard MODBUS-RTU protocol. The | ||
E180-series also support standard PROFIBUS-DP protocol (through an external E180-DP expansion | ||
card). | ||
Coder | E100 | The coder can be connected directly through the DI5 and DI6 terminals on the control panel, and |
simple closed-loop control is available through PID control. Such connection is used in undemanding | ||
situations. | ||
EM60 | The control panel does not have any interface for the coder, and a one-way high-speed pulser can be | |
extended (through DI6). | ||
E102 | The control panel only has one coder interface (DI6). | |
E180 | The control panel does not have any coder interface, and an external coder expansion card is | |
necessary. The inverter supports ABZ incremental coder, UVW incremental coder and resolver. Such | ||
connection enables high-performance VC, and can be used in situations with demanding control | ||
precision requirements. | ||
Motor | E100/E102 | Only for asynchronous motors |
E180 | For asynchronous motors and synchronous motors | |
Display | Operation Information | Given frequency, output frequency, output voltage, busbar voltage, input signal, feedback value, |
module temperature, and synchronous speed of the motor. At most 32 parameters can be displayed in | ||
cycle through the ">>" key. | ||
Fault Information | In the fault protection mode, three pieces of history fault information can be saved. Every piece | |
includes the frequency, current, busbar voltage and I/O terminal status when the fault takes place. | ||
Protection | Inverter Protection | Over-current, over-voltage, module fault protection, under-voltage, overheat, overload, external fault |
protection, EEPROM fault protection, ground protection, and default phase | ||
Inverter Alarm | Locked-rotor protection, overload alarm | |
Instantaneous Power Down | Less than 15 ms: continuous operation | |
More than 15ms: automatic restart | ||
Environment | Ambient Temperature | -10ºC~ 40ºC |
Storage Temperature | -10ºC~ 40ºC | |
Ambient Humidity | Max. 90% RH (No condensation) | |
Altitude/Vibration | Below 1000m; below 0.6g | |
Working Place | No corrosive gas, inflammable gas, oil mist or dust | |
Cooling | Force-air cooling |
Operation | Operation Control Mode | Keyboard/External Terminals/RS485 Communication |
Start Mode | Current Limit/ Voltage/ Heavy-load | |
Start/Stop Time | Digital Settings | |
Start Delay | Digital Settings | |
Emergency Stop | Interrupt the output of the soft starter | |
Current Limit | Start current below this value in the current limit and heavy-load modes | |
Start Voltage | Start voltage can be set digitally in the voltage mode | |
Light-load Control | Belt tripping can be detected | |
Restart | Restart automatically after stopped due to fault | |
Fault Output | Contact output: | |
Multi-functional Relay Output | Start delay, start, operation, stop, complete stop, restart | |
Analog Output | 0-20mA/ 4-20mA, optional | |
Protection | Soft Starter Protection | Over-current, overload, overheat, three-phase imbalance, default phase, light-load, external fault |
Soft Starter Alarming | Emergency stop, light-load, restart | |
Display | Keyboard | |
Operation Information | Ready, start delay, start, operation, stop, fault alarm | |
Parameter Protection | Protect the parameters from being altered | |
Working Conditions | Type | AC-53b 660V Rated Impact-withstanding Voltage: 4kV |
Rated Insulation Voltage | CDRA011T4~CDRA055T4: IP20 | |
Degree of Protection | CDRA075T4~CDRA600T4: IP00 | |
Environment | Ambient Temperature | -10ºC~ 40ºC |
Storage Temperature | -20ºC~ 65ºC | |
Ambient Humidity | 90% RH at most (No condensation) | |
Altitude/Vibration | <1000m;<5.9m/s2 (=0.6g) | |
Working Place | No corrosive gas, inflammable gas, oil mist, or dust | |
Cooling | Natural Cooling |
Model | Brake Unit | Brake Resistance | Power (W) |
CDI-EM60G0R4S2B | Internal, Max. Current of 8A | 400 | 80 |
CDI-EM60G0R75S2B | Internal, Max. Current of 8A | 200 | 160 |
CDI-EM60G1R1S2B | Internal, Max. Current of 8A | 160 | 200 |
CDI-EM60G1R5S2B | Internal, Max. Current of 15A | 120 | 250 |
CDI-EM60G2R2S2B | Internal, Max. Current of 15A | 80 | 400 |
Model | Brake Unit | Brake Resistance | Brake Resistor Power (W) |
S2 (Single-phase 220V) | |||
CDI-E100G0R4S2B | Internal, Max. Current of 8A | 400 | 80 |
CDI-E100G0R75S2B | Internal, Max. Current of 8A | 200 | 160 |
CDI-E100G1R5S2B | Internal, Max. Current of 15A | 120 | 250 |
CDI-E100G2R2S2B | Internal, Max. Current of 15A | 80 | 400 |
T2 (Three-phase 220V) | |||
CDI-E100G0R4T2B | Internal, Max. Current of 8A | 400 | 80 |
CDI-E100G0R75T2B | Internal, Max. Current of 8A | 200 | 160 |
CDI-E100G1R5T2B | Internal, Max. Current of 15A | 120 | 250 |
CDI-E100G2R2T2B | Internal, Max. Current of 25A | 80 | 400 |
T4 (Three-phase 380V) | |||
CDI-E100G0R75T4B | Internal, Max. Current of 8A | 600 | 160 |
CDI-E100G1R5T2B | Internal, Max. Current of 8A | 400 | 250 |
CDI-E100G2R2T4B | Internal, Max. Current of 15A | 250 | 400 |
CDI-E100G3R7T4B | Internal, Max. Current of 15A | 150 | 600 |
CDI-E100G5R5/P7R5T4B | Internal, Max. Current of 40A | 100 | 1000 |
CDI-E100G7R5/P0R11T4B | Internal, Max. Current of 40A | 75 | 1200 |
CDI-E100G011/P015T4BL | Internal, Max. Current of 50A | 50 | 2000 |
CDI-E100G015/P018.5T4BL | Internal, Max. Current of 75A | 40 | 2500 |
CDI-E100G0185/P022T4 | Internal, Max. Current of 50A Connect to External CDI-BR-50 | 30 | 4000 |
CDI-E100G022T4 | Internal, Max. Current of 50A Connect to External CDI-BR-50 | 30 | 4000 |
Model | Brake Unit | Brake Resistance | Brake Resistor Power (W) |
T2 (Three-phase 220V) | |||
CDI-E180G0R4T2B | Internal, Max. Current of 10A | 350 | 160 |
CDI-E180G0R75T2B | Internal, Max. Current of 10A | 300 | 160 |
CDI-E180G1R5T2B | Internal, Max. Current of 25A | 100 | 250 |
CDI-E180G2R2T2B | Internal, Max. Current of 25A | 75 | 400 |
CDI-E180G3R7T2B | Internal, Max. Current of 40A | 45 | 600 |
CDI-E180G5R5T2B | Internal, Max. Current of 50A | 30 | 1000 |
CDI-E180G7R5T2BL | Internal, Max. Current of 75A | 20 | 1200 |
CDI-E180G011T2 | Internal, Max. Current of 50A (Connect to External CDI-BR-50) | 16 | 2000 |
CDI-E180G015T2 | CDI-BR-100 | 12 | 2500 |
CDI-E180G018.5T2 | CDI-BR-100 | 20/2 | 4000 |
CDI-E180G022T2 | CDI-BR-100 | 16/2 | 4000 |
CDI-E180G030T2 | Internal, Max. Current of 75A (Connect to External CDI-BR-50) | 13.6/2 | 6000 |
T4 (Three-phase 380V) | |||
CDI-E180G0R75T4B | Internal, Max. Current of 10A | 600 | 160 |
CDI-E180G1R5T4B | Internal, Max. Current of 10A | 400 | 250 |
CDI-E180G2R2T4B | Internal, Max. Current of 15A | 250 | 400 |
CDI-E180G3R7/P5R5T4B | Internal, Max. Current of 25A | 150 | 600 |
CDI-E180G5R5MT4B | Internal, Max. Current of 40A | 100 | 1000 |
CDI-E180G5R5/P7R5T4B | Internal, Max. Current of 40A | 100 | 1000 |
CDI-E180G7R5/P011T4B | Internal, Max. Current of 40A | 75 | 1200 |
CDI-E180G011MT4B | Internal, Max. Current of 50A | 50 | 2000 |
CDI-E180G0011/P015T4BL | Internal, Max. Current of 50A | 50 | 2000 |
CDI-E180G015/P018.5T4BL | Internal, Max. Current of 75A | 40 | 2500 |
CDI-E180G018.5/P022T4 | Internal, Max. Current of 50A (Connect to External CDI-BR-50) | 30 | 4000 |
CDI-E180G022/P030T4 | Internal, Max. Current of 75A (Connect to External CDI-BR-50) | 30 | 4000 |
CDI-E180G030/P037T4 | Internal, Max. Current of 50A (Connect to External CDI-BR-50) | 20 | 6000 |
CDI-E180G037/P045T4 | CDI-BR-100 | 16 | 9000 |
CDI-E180G045/P055T4 | CDI-BR-100 | 13.6 | 9000 |
CDI-E180G055/P075T4 | CDI-BR-100 | 20/2 | 12000 |
CDI-E180G075/P093T4 | CDI-BR-200 | 13.6/2 | 18000 |
CDI-E180G093/P110T4 | CDI-BR-200 | 20/3 | 18000 |
CDI-E180G110/P132T4 | CDI-BR-200 | 20/3 | 24000 |
CDI-E180G132/P160T4 | CDI-BR-200 | 20/4 | 36000 |
CDI-E180G160/P185T4 | CDI-BR-400 | 13.6/4 | 45000 |
CDI-E180G185/P200T4 | CDI-BR-400 | 13.6/5 | 45000 |
CDI-E180G200/P220T4L | CDI-BR-400 | 13.6/5 | 54000 |
CDI-E180G250/P280T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G280/P315T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G315/P355T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G355/P375T4L | CDI-BR-400 | 13.6/6 | 54000 |
CDI-E180G375T4L | CDI-BR-400 | 13.6/6 | 63000 |
CDI-E180G400T4L | CDI-BR-600 | 13.6/7 | 63000 |
CDI-E180G400T4L | CDI-BR-600 | 13.6/7 | 72000 |
CDI-E180G500T4L | CDI-BR-600 | 13.6/8 | 72000 |
CDI-E180G500T4L | CDI-BR-600 | 13.6/8 | 81000 |
CDI-E180G630T4L | CDI-BR-600 | 13.6/9 | 81000 |
CDI-E180G200T4L | CDI-BR-600 | 13.6/9 | 90000 |
CDI-E180P250T4L | 2 CDI-BR-400 | 13.6/10 | 18000 |
WHY CHOOSE US?
Q1.Are you manufacturer or trading company?
A.We are the only manufacturer of electrical products.
Welcome to visit our factory at any time.
Q 2. what's the payment term?
A. We accept T/T, L/C, WESTERN UNION
Q 3. What's the delivery time ?
A. Normal model 1-3days,because we have ability to do the stock.
For big order,it takes about 15-20days.
Q 4. What is the standard of package?
A. Export standard package or special package according to customer requirement
.
Q 5. what kind of product quality your factory offer?
A. We are top 3 from Chinese market.We offer top quality to help client to get more market.
Q 6. Do you accept OEM business?
A. We do OEM .
Q 7.Which market do you already sell?
A.We already ship to Middle East, Asia, Russia ,Afria etc.
Q8. what kind of certificate you have ?
A.We have ISO9001, CE, CCC,etc.
Hangzhou Delixi Group Co., Ltd is one of the three Delixi Group advanced manufacturing bases and one of the largest instrument and electric power automation production bases in China.Its leading industries are household electrical appliance, energy meter, frequency converter, three-way catalytic converter, transmitter, automation and capacitors.In recent three years, the company, since developing rapidly and soundly, has an annual growth rate of 30% in terms of sales and it is one of the fast growing companies with considerable returns in the industry.
Hangzhou Delixi, following the international state-of-art technology, has set up a high-tech eco-industrial park with the investment of 2 billion Yuan, and the park is equipped with domestically leading processing and inspection equipment.Moreover, the company has 1000 sets production equipment and 100 production lines;And also it has set up technological center to focus on the development of high-tech products and improvement of technologies and processes.In 2007, its frequency converter is rated as a high-tech product, and the frequency converter company is recognized as the provincial high-tech company.Its transmitter is developed by cooperation with ABB Company.The automatic surveillance system for substation is one of the Top 10 science and technology planning project of Xihu District in 2007.
We are dedicated to providing efficient and stable technical solutions for customers and continuously improving the efficiency of energy use.Our company, by applying the internationally advanced variable frequency control technology and the actual needs of domestic customers, has independently researched, developed and manufactured inverter welding equipment, including MMA welding machine, TIG welding machine, TIG/MMA welding machine, CO2 MIG welding machine, air plasma cutter, AC/DC TIG welding machine, submerged arc welding machine and inverter full-function digital welding machine, etc.We have civil welding machine, industrial welding machine and digital welding machines, and all our products are widely applied in aviation, shipbuilding, bridges, constructions, automobiles, pressure vessels and industries of mineral and metal processing.