Basis Info Modell Nr

Featured Products

Basis Info
  • Modell Nr.: CDI-E180G315/P355T4
  • Anwendung : High-Performance-Transducer , Drei Phase Transducer , Allgemeine Transducer , Einphasen-Transducer , High Frequency Converter Transducer
  • Ausgabetyp : Dreifach
  • Prinzip der Arbeit : Vector Control Transducer
  • Switch Mode : PWM-Steuerung
  • Spannung der Stromversorgung : Mittelspannungs Variable Frequency Drive-
  • Link der Transformation : AC-DC-AC-Variable Frequency Drive
  • Art der DC-Strom : Aktuelle Variable Frequency Drive-
  • Funktion : Konstante Drehmoment Universal Type
Zusätzliche Informationen..
  • Trademark: DELIXI
  • Packing: Standard Exporting Package
  • Standard: CE, CCC
  • Origin: Zhejiang China(Mainland)
  • HS Code: 8504409999
  • Production Capacity: 10, 000 Per Month
Produktbeschreibung

Product Name: 3 Phase Vector Control AC Drive 315KW Large AC Drive

* Dear friends, you can tell me your requirements, I will select models for you if needed.


1. "High precision", "high performance", "high cost-effective".
To satisfy the increasingly higher requirements on the industrial production of frequency inverters, Hangzhou Delixi develops a new E series frequency inverter aiming at the market demands. Compared with the old frequency inverters, its precision and performance are improved substantially besides its optimized structure and appearance. Its powerful built-in function may better fulfill the needs of different industries.

2. High control precision
Speed regulation scope
1: 100 (SVC) 1: 1000(VC)
Speed stabilizing scope
0.5%(SVC) 0.02%(VC)
Torque control precision
5% (VC)

3. Rapid torque response
SVC: Torque response < 20ms
VC: Torque response < 5ms

4. High starting torque

SVC: 0.5 Hz may provide 150% starting torque
VC: 0 HZ may provide 180% torque at zero speed

5. Various vector controls of motors are available

E180 Series may drive asynchronous motor and synchronous motor.

6. Diversified menu display modes

7. Function of built-in timer

It has two built-in timers to collect input timing signals and realize the output of timing signals. Such function may be used separately or in any combination.

8. Built-in virtual time-delay relay

It has 5 built-in virtual time-delay relays to conduct simple logic operation for multi-functional output terminals and digital input terminal signals. The logic result may be considered as equivalent to input terminal function and also may be output from the multi-functional output terminals. Moreover, the logic results may be conducted with time-delay and negation operations.

9. Function of built-in operating module

One quad operating module is built in. Such module may conduct simple addition, subtraction, multiplication, division, judgment of size and integral operations. Each operation has 4 input directing addresses and one output directing address. The input directing address is function code.

10. Function of rapid current limiter

In the case the current exceeds the current protection point, the rapid current limiter may keep the current within the current protection point to prevent frequently sending over-current alarm by the frequency inverter and protect the equipment.

11. Excellent capability of power drive control

The maximum drive capability of 24V output power of E-series frequency inverter, equipped with current limiting alarm function, may be 300mA.

The user may use it to supply power to text, touch screen, PLC and relay instead of connecting to an external switch.



Item

Specification

Control

Control Mode

V/F control

Open-loop Vector Control (SVC)

Vector Control (VC) (Not applicable to E100/E102/EM60 series)

Frequency Precision

Digital: 0.02%

Analog: 0.1%

V/F Curve

Linear, square root, any V/F

Overload Capacity

G-type: 150% rated current for 60s; 180% rated current for 3s

P-type: 120% rated current for 60s; 150% rated current for 3s

Start Torque

G-type: 0.5Hz/150% (SVC); 0Hz/180% (VC)

Speed Adjustment Range

1:100 (SVC) 1:1000 (VC)

0.5% (SVC) 0.02% (VC)

Torque Precision

5% (VC)

Torque Compensation

Manual torque compensation (0.10%-30.0%); Automatic torque compensation

Operating Mode

Key-board, terminal, RS485 communication

Basic Type Function

Frequency Source

14 main sources, 14 auxiliary sources.

Easy switch between different modes.

Diversified input modes for every source: keyboard potentiometer, external analog,

digital setting, pulse frequency, multi-speed, simple PLC, communication, computing

results, etc.

Torque Source

14 torque sources, including digital setting, external analog, pulse setting,

multi-order, communication, computing results, etc.

Acceleration and Deceleration Time

4 groups of lines (can be switched through the option terminals); S Curve 1, S Curve 2

Emergency Stop

Interrupt the output instantaneously

Multi-speed

16-shift speeds at most; can be switched by different combination of order terminals

Simple PLC

Continuous operation of 16-shift speeds; the acceleration/deceleration time, operating

time and frequency source for every shift can be set separately

Inching Control

Inching frequency and inching acceleration/deceleration time can be set separately;

Inching can be prioritized in process.

Rotating-speed Track

Track the start speed and operating speed of the inverter's load

Length and Distance Control

Length and distance control through pulse inputs

Counting

Counting through pulse inputs

Swing Frequency

For winding machines in the textile industry

Internal PID

Closed-loop process control system is available

AV R

Ensure constant output in case of fluctuating grid voltage

DC Brake

Quick and stable parking is available

Slip Compensation

Compensate the slip deviation due to increased load

Hopping Frequency

Prevent resonance with the load

Droop Function

Balance the load rate of different motors which drive the same load

Timing

Automatic stop at a given time


Item

Specification

Enhanced Function

Internal Virtual Time
Delay Relay

Simple logic programming for the multi-functional output terminals and the digital input terminals.

The logic results can be equivalent to the digital input terminal function, and can be output through

the multi-functional output terminals

Internal Timer

Two internal timers to collect timing input signals and to output timing signals.

The two timers can be used separately or together

Internal Math

One internal 4-way math operation module for elementary arithmetic operations, numerical

Operation Module

magnitude judgment and integral operation

Communication

E100

The control panel has a RS485 communication interface which supports standard MODBUS-RTU

protocol

E102/E180/EM60

The control panel does not have a RS485 communication interface, and an external 485

communication expansion card shall be connected. Support standard MODBUS-RTU protocol. The

E180-series also support standard PROFIBUS-DP protocol (through an external E180-DP expansion

card).

Coder

E100

The coder can be connected directly through the DI5 and DI6 terminals on the control panel, and

simple closed-loop control is available through PID control. Such connection is used in undemanding

situations.

EM60

The control panel does not have any interface for the coder, and a one-way high-speed pulser can be

extended (through DI6).

E102

The control panel only has one coder interface (DI6).

E180

The control panel does not have any coder interface, and an external coder expansion card is

necessary. The inverter supports ABZ incremental coder, UVW incremental coder and resolver. Such

connection enables high-performance VC, and can be used in situations with demanding control

precision requirements.

Motor

E100/E102

Only for asynchronous motors

E180

For asynchronous motors and synchronous motors

Display

Operation Information

Given frequency, output frequency, output voltage, busbar voltage, input signal, feedback value,

module temperature, and synchronous speed of the motor. At most 32 parameters can be displayed in

cycle through the ">>" key.

Fault Information

In the fault protection mode, three pieces of history fault information can be saved. Every piece

includes the frequency, current, busbar voltage and I/O terminal status when the fault takes place.

Protection

Inverter Protection

Over-current, over-voltage, module fault protection, under-voltage, overheat, overload, external fault

protection, EEPROM fault protection, ground protection, and default phase

Inverter Alarm

Locked-rotor protection, overload alarm

Instantaneous Power Down

Less than 15 ms: continuous operation

More than 15ms: automatic restart

Environment

Ambient Temperature

-10ºC~ 40ºC

Storage Temperature

-10ºC~ 40ºC

Ambient Humidity

Max. 90% RH (No condensation)

Altitude/Vibration

Below 1000m; below 0.6g

Working Place

No corrosive gas, inflammable gas, oil mist or dust


Cooling

Force-air cooling

Operation

Operation Control Mode

Keyboard/External Terminals/RS485 Communication

Start Mode

Current Limit/ Voltage/ Heavy-load

Start/Stop Time

Digital Settings

Start Delay

Digital Settings

Emergency Stop

Interrupt the output of the soft starter

Current Limit

Start current below this value in the current limit and heavy-load modes

Start Voltage

Start voltage can be set digitally in the voltage mode

Light-load Control

Belt tripping can be detected

Restart

Restart automatically after stopped due to fault

Fault Output

Contact output:

Multi-functional Relay Output

Start delay, start, operation, stop, complete stop, restart

Analog Output

0-20mA/ 4-20mA, optional

Protection

Soft Starter Protection

Over-current, overload, overheat, three-phase imbalance, default phase, light-load, external fault

Soft Starter Alarming

Emergency stop, light-load, restart

Display

Keyboard


Operation Information

Ready, start delay, start, operation, stop, fault alarm

Parameter Protection

Protect the parameters from being altered

Working Conditions

Type

AC-53b 660V Rated Impact-withstanding Voltage: 4kV

Rated Insulation Voltage

CDRA011T4~CDRA055T4: IP20

Degree of Protection

CDRA075T4~CDRA600T4: IP00

Environment

Ambient Temperature

-10ºC~ 40ºC

Storage Temperature

-20ºC~ 65ºC

Ambient Humidity

90% RH at most (No condensation)

Altitude/Vibration

<1000m;<5.9m/s2 (=0.6g)

Working Place

No corrosive gas, inflammable gas, oil mist, or dust

Cooling

Natural Cooling

Model

Brake Unit

Brake Resistance

Power (W)

CDI-EM60G0R4S2B

Internal, Max. Current of 8A

400

80

CDI-EM60G0R75S2B

Internal, Max. Current of 8A

200

160

CDI-EM60G1R1S2B

Internal, Max. Current of 8A

160

200

CDI-EM60G1R5S2B

Internal, Max. Current of 15A

120

250

CDI-EM60G2R2S2B

Internal, Max. Current of 15A

80

400









Model

Brake Unit

Brake Resistance

Brake Resistor Power (W)


S2 (Single-phase 220V)



CDI-E100G0R4S2B

Internal, Max. Current of 8A

400

80

CDI-E100G0R75S2B

Internal, Max. Current of 8A

200

160

CDI-E100G1R5S2B

Internal, Max. Current of 15A

120

250

CDI-E100G2R2S2B

Internal, Max. Current of 15A

80

400


T2 (Three-phase 220V)



CDI-E100G0R4T2B

Internal, Max. Current of 8A

400

80

CDI-E100G0R75T2B

Internal, Max. Current of 8A

200

160

CDI-E100G1R5T2B

Internal, Max. Current of 15A

120

250

CDI-E100G2R2T2B

Internal, Max. Current of 25A

80

400


T4 (Three-phase 380V)



CDI-E100G0R75T4B

Internal, Max. Current of 8A

600

160

CDI-E100G1R5T2B

Internal, Max. Current of 8A

400

250

CDI-E100G2R2T4B

Internal, Max. Current of 15A

250

400

CDI-E100G3R7T4B

Internal, Max. Current of 15A

150

600

CDI-E100G5R5/P7R5T4B

Internal, Max. Current of 40A

100

1000

CDI-E100G7R5/P0R11T4B

Internal, Max. Current of 40A

75

1200

CDI-E100G011/P015T4BL

Internal, Max. Current of 50A

50

2000

CDI-E100G015/P018.5T4BL

Internal, Max. Current of 75A

40

2500

CDI-E100G0185/P022T4

Internal, Max. Current of 50A
Connect to External CDI-BR-50

30

4000

CDI-E100G022T4

Internal, Max. Current of 50A
Connect to External CDI-BR-50

30

4000





Model

Brake Unit

Brake Resistance

Brake Resistor Power (W)


T2 (Three-phase 220V)



CDI-E180G0R4T2B

Internal, Max. Current of 10A

350

160

CDI-E180G0R75T2B

Internal, Max. Current of 10A

300

160

CDI-E180G1R5T2B

Internal, Max. Current of 25A

100

250

CDI-E180G2R2T2B

Internal, Max. Current of 25A

75

400

CDI-E180G3R7T2B

Internal, Max. Current of 40A

45

600

CDI-E180G5R5T2B

Internal, Max. Current of 50A

30

1000

CDI-E180G7R5T2BL

Internal, Max. Current of 75A

20

1200

CDI-E180G011T2

Internal, Max. Current of 50A (Connect to External CDI-BR-50)

16

2000

CDI-E180G015T2

CDI-BR-100

12

2500

CDI-E180G018.5T2

CDI-BR-100

20/2

4000

CDI-E180G022T2

CDI-BR-100

16/2

4000

CDI-E180G030T2

Internal, Max. Current of 75A (Connect to External CDI-BR-50)

13.6/2

6000


T4 (Three-phase 380V)



CDI-E180G0R75T4B

Internal, Max. Current of 10A

600

160

CDI-E180G1R5T4B

Internal, Max. Current of 10A

400

250

CDI-E180G2R2T4B

Internal, Max. Current of 15A

250

400

CDI-E180G3R7/P5R5T4B

Internal, Max. Current of 25A

150

600

CDI-E180G5R5MT4B

Internal, Max. Current of 40A

100

1000

CDI-E180G5R5/P7R5T4B

Internal, Max. Current of 40A

100

1000

CDI-E180G7R5/P011T4B

Internal, Max. Current of 40A

75

1200

CDI-E180G011MT4B

Internal, Max. Current of 50A

50

2000

CDI-E180G0011/P015T4BL

Internal, Max. Current of 50A

50

2000

CDI-E180G015/P018.5T4BL

Internal, Max. Current of 75A

40

2500

CDI-E180G018.5/P022T4

Internal, Max. Current of 50A (Connect to External CDI-BR-50)

30

4000

CDI-E180G022/P030T4

Internal, Max. Current of 75A (Connect to External CDI-BR-50)

30

4000

CDI-E180G030/P037T4

Internal, Max. Current of 50A (Connect to External CDI-BR-50)

20

6000

CDI-E180G037/P045T4

CDI-BR-100

16

9000

CDI-E180G045/P055T4

CDI-BR-100

13.6

9000

CDI-E180G055/P075T4

CDI-BR-100

20/2

12000

CDI-E180G075/P093T4

CDI-BR-200

13.6/2

18000

CDI-E180G093/P110T4

CDI-BR-200

20/3

18000

CDI-E180G110/P132T4

CDI-BR-200

20/3

24000

CDI-E180G132/P160T4

CDI-BR-200

20/4

36000

CDI-E180G160/P185T4

CDI-BR-400

13.6/4

45000

CDI-E180G185/P200T4

CDI-BR-400

13.6/5

45000

CDI-E180G200/P220T4L

CDI-BR-400

13.6/5

54000

CDI-E180G250/P280T4L

CDI-BR-400

13.6/6

54000

CDI-E180G280/P315T4L

CDI-BR-400

13.6/6

54000

CDI-E180G315/P355T4L

CDI-BR-400

13.6/6

54000

CDI-E180G355/P375T4L

CDI-BR-400

13.6/6

54000

CDI-E180G375T4L

CDI-BR-400

13.6/6

63000

CDI-E180G400T4L

CDI-BR-600

13.6/7

63000

CDI-E180G400T4L

CDI-BR-600

13.6/7

72000

CDI-E180G500T4L

CDI-BR-600

13.6/8

72000

CDI-E180G500T4L

CDI-BR-600

13.6/8

81000

CDI-E180G630T4L

CDI-BR-600

13.6/9

81000

CDI-E180G200T4L

CDI-BR-600

13.6/9

90000

CDI-E180P250T4L

2 CDI-BR-400

13.6/10

18000

WHY CHOOSE US?

Q1.Are you manufacturer or trading company?
A.We are the only manufacturer of electrical products.
Welcome to visit our factory at any time.

Q 2. what's the payment term?
A. We accept T/T, L/C, WESTERN UNION

Q 3. What's the delivery time ?
A. Normal model 1-3days,because we have ability to do the stock.
For big order,it takes about 15-20days.

Q 4. What is the standard of package?
A. Export standard package or special package according to customer requirement
.
Q 5. what kind of product quality your factory offer?
A. We are top 3 from Chinese market.We offer top quality to help client to get more market.

Q 6. Do you accept OEM business?
A. We do OEM .
Q 7.Which market do you already sell?
A.We already ship to Middle East, Asia, Russia ,Afria etc.

Q8. what kind of certificate you have ?
A.We have ISO9001, CE, CCC,etc.

Produkttyp
» » »

Kontaktiere uns

Bitte zögern Sie nicht, Ihre Anfrage im untenstehenden Formular zu stellen. Wir werden Ihnen innerhalb von 24 Stunden antworten